SharqStor FS 4240 FC-SATA II Detailed Specifications

Back to Specifications
Back to Product

RAID

  • Multiple arrays configurable with dedicated or global hot spares
  • RAID levels supported: RAID 0, 1 (0+1), 3, 5, 10, 30, 50, NRAID and JBOD
  • Online expansion by Adding new drives / Copying and replacing drives with drives of larger capacity
  • Automatic background rebuilds
  • Configurable stripe size and write policy per array
  • In degraded mode: skips irreparable blocks to continue rebuild
  • In normal operation: data-block verification and repair

Host Interface

  • Four (4) FC-2G host channels with embedded bypass circuit to eight (8) FC ports on two (2) hot-swappable, independent host connection modules
  • DIP switch settings to change host port attributes
  • Auto-negotiate FC-AL, point-to-point, or switched fabric
  • Tagged command queuing up to 256
  • Variable stripe size per logical drive
  • Optimization setting for random or sequential I/Os

Drive Interface

  • Twentyfour (24) hot-swappable 3Gbps SATA-II drive trays that accommodate 1-inch pitch, 3.5-inch SATA-II or SATA-I disk drives
  • Automatic bad-sector reassignment
  • Dedicated bandwidth to each connected drive

Management

  • Firmware-embedded utility via LCD keypad or RS-232C port
  • Host-side SES emulation with pass-through to back-end SES emulation
  • VT-100 terminal emulation via RS-232C
  • Telnet access via onboard Ethernet port
  • 10/100 BaseT Ethernet for out-of-band management
  • Two (2) COM ports for local access to firmware-embedded utility and UPS connectivity
  • Firmware-embedded Java-based RAIDWatch manager:

    * Graphical user interface
    * Local/remote management; in-band or out-of-band via TCP/IP
    * Centralized management to monitor and administer multiple RAID units on one screen
    * Secure link over SSL

  • Configuration Client for easy access to the configuration utility screen
  • SNMP 2.0 MIBs with get and set commands

SAN Management

  • Up to 1024 LUNs (if sufficiently large memory is used with the proper settings)

System Components

  • Two (2) RAID controller modules
  • Two (2) 256MB DDR RAM DIMM modules (pre-installed on the controller modules)
  • Two (2) hot-swappable, redundant, dual-fan cooling modules running in high/low speeds
  • Sixteen (16) hot-swappable drive trays
  • Two (2) independent battery backup units (BBUs)
  • One (1) enclosure configuration card
  • Two (2) host connection modules

Indicators

  • Onboard alarm is triggered when one of the following fails:

    * RAID controller module
    * Cooling module
    * Power supply unit
    * Hard drive
    * BBU module
    * Host connection module

  • Module status LED indicators:

    * Two (2) per drive tray
    * Two (2) per cooling module
    * One (1) per power supply unit
    * One (1) per BBU module
    * Three (3) per LCD panel
    * Five (5) per RAID controller module
    * Two (2) per Ethernet port
    * Two (2) per FC port (One LED is reserved)

  • Module failure alert through I2C bus
  • Event notifications sent over email, fax, LAN broadcast, SNMP traps, MSN messenger, ICQ, SMS short messages
  • System alerts through Java-based RAIDWatch manager

Interfaces

  • Eight (8) FC ports, each using a short-wavelength adapter
  • Two (2) COM ports on each controller module for RS-232C serial port (38400, n, 8, 1) and UPS support
  • One (1) 10/100BaseT Ethernet port on each controller module

Power Supply Module

  • Two (2) 12V 405W  redundant, hot-swappable power supplies with PFC

Chassis Form Factor

  • Industry standard 19" rack-mountable 4U chassis
  • Dimensions (inch - WxDxH): 19" x 20.2" x 6.86"
  • Dimensions (mm - WxDxH):  483 x 514 x 175

Regulatory

  • FCC
  • CE
  • CB