RAID
|
- Multiple arrays configurable with dedicated or global hot spares
- RAID levels supported: RAID 0, 1 (0+1), 3, 5, 10, 30, 50, NRAID and JBOD
- Online expansion by Adding new drives / Copying and replacing drives with
drives of larger capacity
- Automatic background rebuilds
- Configurable stripe size and write policy per array
- In degraded mode: skips irreparable blocks to continue rebuild
- In normal operation: data-block verification and repair
|
|
Host Interface
|
- Four (4) FC-2G host channels with embedded bypass circuit to eight (8) FC
ports on two (2) hot-swappable, independent host connection modules
- DIP switch settings to change host port attributes
- Auto-negotiate FC-AL, point-to-point, or switched fabric
- Tagged command queuing up to 256
- Variable stripe size per logical drive
- Optimization setting for random or sequential I/Os
|
|
Drive Interface
|
- Twentyfour (24) hot-swappable 3Gbps SATA-II drive trays that accommodate
1-inch pitch, 3.5-inch SATA-II or SATA-I disk drives
- Automatic bad-sector reassignment
- Dedicated bandwidth to each connected drive
|
|
|
Management
|
- Firmware-embedded utility via LCD keypad or RS-232C port
- Host-side SES emulation with pass-through to back-end SES emulation
- VT-100 terminal emulation via RS-232C
- Telnet access via onboard Ethernet port
- 10/100 BaseT Ethernet for out-of-band management
- Two (2) COM ports for local access to firmware-embedded utility and UPS
connectivity
- Firmware-embedded Java-based RAIDWatch manager:
* Graphical user interface
* Local/remote management; in-band or out-of-band via TCP/IP
* Centralized management to monitor and administer multiple RAID units on
one screen
* Secure link over SSL
- Configuration Client for easy access to the configuration utility screen
- SNMP 2.0 MIBs with get and set commands
|
|
SAN Management
|
- Up to 1024 LUNs (if sufficiently large memory is used with the proper
settings)
|
|
|
System Components
|
- Two (2) RAID controller modules
- Two (2) 256MB DDR RAM DIMM modules (pre-installed on the controller modules)
- Two (2) hot-swappable, redundant, dual-fan cooling modules running in
high/low speeds
- Sixteen (16) hot-swappable drive trays
- Two (2) independent battery backup units (BBUs)
- One (1) enclosure configuration card
- Two (2) host connection modules
|
|
|
Indicators
|
- Onboard alarm is triggered when one of the following fails:
* RAID controller module
* Cooling module
* Power supply unit
* Hard drive
* BBU module
* Host connection module
- Module status LED indicators:
* Two (2) per drive tray
* Two (2) per cooling module
* One (1) per power supply unit
* One (1) per BBU module
* Three (3) per LCD panel
* Five (5) per RAID controller module
* Two (2) per Ethernet port
* Two (2) per FC port (One LED is reserved)
- Module failure alert through I2C bus
- Event notifications sent over email, fax, LAN broadcast, SNMP traps, MSN
messenger, ICQ, SMS short messages
- System alerts through Java-based RAIDWatch manager
|
|
|
Interfaces
|
- Eight (8) FC ports, each using a short-wavelength adapter
- Two (2) COM ports on each controller module for RS-232C serial port (38400,
n, 8, 1) and UPS support
- One (1) 10/100BaseT Ethernet port on each controller module
|
|
Power Supply Module
|
- Two (2) 12V 405W redundant, hot-swappable power supplies with PFC
|
|
|
Chassis Form Factor
|
- Industry standard 19" rack-mountable 4U chassis
- Dimensions (inch - WxDxH): 19" x 20.2" x 6.86"
- Dimensions (mm - WxDxH): 483 x 514 x 175
|
|
Regulatory
|
|